百佳泰於2023年6月9日獲得USB-IF協會授權,正式取得USB Power Delivery EPR認證資格。相關認證要求的測試項目以及測試設備如下:

目前可取證的USB Power Delivery EPR產品種類尚有限制,USB-IF要求認證產品只能夠有一個USB Type-C® port為EPR capable source port。以下兩項目前無法取證的產品為例:

  1. 產品上除了有EPR capable source port也有EPR capable sink port
  2. 產品上除了有EPR capable source port也有SPR capable source port

除了上述限制外,另一點須留意的是:因為EPR的AVS為必需要支援的功能, 所以不允許不支援AVS的EPR capable source port取證

最新USB-IF compliance updates如下:

 Deprecation of EHCI Testing. USB2CV and EHCI IOP

Decrease to One Test Equipment Solution for SPR Products

注意事項:EX-350只支援Protocol相關測項, 故需要另外用其他設備補測Physical & Power相關測項

The USB-IF has recently confirmed that the RFI tests will not be applicable to hubs for the time being

注意事項:The temporary waiver can be granted by USB-IF until February, Y2024

㊃ FRS & USB4 should be run in the latest USB Power Delivery CTS for informational purpose

㊄ TEST.PD.PROT.ALL3.8 in the latest USB Power Delivery CTS

注意事項:
Respond with the correct revision: Pass
Respond with Not Supported: Temporary Waiver
Respond with nothing: Fail

㊅ COMMON.CHECK.PD.9 in the latest USB Power Delivery CTS

PD CTS update 詳細資訊:


PD Spec. update詳細資訊:


注意事項:The CTS will always be testing against the most current version of the base CTS. Any failures relating to previous versions will go through the waiver process

㊆ Define Vbus slew rate measurements in the latest USB Power Delivery CTS

詳細資訊:

◈ Affected Test item
➱ PD.PS.SRC.1 Multiple Request Load Test
➱ PD.PS.SRC.2 PDO Transitions
➱ PD.PS.SNK.3 Multiple Request Load Test Post PR Swap
◈ Vbus slew rate measurements (Appendix E)
➱ Turn all filtering and sample averaging off and work only with the raw signal samples
➱ Collect data samples with rate at least 20uS/Sample
➱ Start collecting signal samples after receiving Accept Message and before sending the last bit of GoodCRC Message. Record the Voltage Level as V1
➱ Stop collecting signal samples upon receiving PS_RDY Message. Record the Voltage Level as V2. –    Calculate the difference ΔV = |V2 – V1|
➱ If ΔV < 3.5V, the slew rate measurement could not be accurately calculated, and the measurement disregarded.
➱ Find the first sample that exceeds V1 + 0.1*ΔV for the Positive Transition (V2>V1) or getting below V2 + 0.9*ΔV + for the Negative Transitions (V2< V1) and corresponding sample number Sn_A from the last bit of GoodCRC– point A
➱ Find the first sample that exceeds V1 + 0.9* ΔV + for the Positive Transitions or getting below V2 + 0.1*ΔV + for the Negative Transitions and corresponding sample number Sn_B from the last bit of GoodCRC – point B
➱ Find SR = (Vpoint_B – Vpoint_A)/(Sn_B – Sn_A)*R

㊇ Remove the monotonicity requirement

詳細資訊:

• Affected Test item
SPT.1 Load Test in USB Type-C and PD Source Power Requirements CTS

• If USB-IF QuadraMax reports the monotonicity issue, the vendors can ignore it and no waiver is required

㊈ Update to PPS Requirements

詳細資訊:

• Affected Test item
SPT.6 PPS Voltage Step Test in USB Type-C and PD Source Power Requirements CTS

• If USB-IF QuadraMax reports the min voltage issue (3.3V), the vendors can request a wavier


USB Type-C®and USB-C® are registered trademarks of USB Implementers Forum.

若您想更了解USB-IF compliance updates,或是有任何USB Power Delivery EPR認證需求,歡迎立即填寫諮詢表單,將有專人盡速與您聯繫。